Allmand 2220/SE Light Tower

The Allmand 2220/SE is a light tower.

0
Parts

Troubleshooting

5

Symptoms & remedies

SymptomRemedy
Display not functioning properly or not functioning at all.Check wiring, lamps and connections. Replace lamp elements or controller if necessary. Check batteries, re-charge or replace if necessary.
No power to system.Check circuit breakers on controller. Allow to automatically reset if tripped. Check wiring. Replace controller.
Operational time is less than desired.Check battery condition. Charge batteries with heavy-duty AC charger. Use hydrometer to ensure that batteries are fully charged before putting unit into service. (See BATTERY MAINTENANCE section). Check solar panels. (See ARRAY MAINTENANCE section.)
LVD lamp illuminated or system shut down.Charge batteries using properly sized AC charger until voltmeter or hydrometer indicates batteries are fully charged.
Batteries will not fully charge.Check battery condition. (See BATTERY MAINTENANCE section.) Replace if necessary.