SymptomCauseRemedy
Oil leakage past spool seal into spool capIf spool cap contains oil, replace spool seal o-ring. If o-ring retainer is “belled” check for restriction from “out” port reservoir.See item 30.
Broken return springsReplace springs. See item 30.
Bent spoolReturn for factory repair or replace with new spool section. See item 30.
Foreign particlesClean system and valve.
Misalignment of control handle linkage or spool bonnetCheck linkage for binding condition; loosen bonnet, operate valve to realign, and retighten.
Spool not moved to full strokeSpool travel should be 5/16
Poppet in control valve not holdingClean check poppet(s) carefully. Ensure free movement and proper seating or replace check poppet(s). See item 30.
Damaged or worn spool sealsReplace spool end seals.
Ball in anti-cavitation valve stuck or not seated properlyClean anti-cavitation valve carefully. Assure that checks move freely and seat properly or replace cartridge. See item 30.
Valve cap and center return mechanism bindingLoosen screws holding cap on valve (ref. Item#2 P.22). Operate valve spool and retighten screws.
Valve malfunction due to dirt or packing materialDirt and shreds of packing material are the usual causes of valve malfunction. Be sure that oil supply is kept clean. Use only factory supplied packings in cylinder repair. Fittings and hoses must be clean before being removed.