Troubleshooting
4Symptoms & remedies
| Symptom | Cause | Remedy |
|---|---|---|
| Generator output at GFCI receptacle reads less than 120 volts +10% | Generator may be malfunctioning; issue with the main circuit breaker; issue with the pop out receptacle circuit breaker; issue with the GFCI receptacle by itself; issue with the wiring between any of these | Refer to page 2 for additional troubleshooting |
| Generator output at GFCI receptacle shows zero or low voltage | Generator; generator capacitor; wiring from the generator to the main circuit breaker | Test the generator voltage at the main circuit breaker; refer to the troubleshooting flowchart (Section 1.6 forward) to further isolate the problem |
| 120 volts +10% is not measured at each top (input) terminal of the main breaker | Generator; generator capacitor; wiring from the generator to the main circuit breaker | Refer to the troubleshooting flowchart (Section 1.6 forward) to further isolate the problem |
| 120 volts +10% is not measured at each terminal of the main breaker | Main breaker is faulty | Main breaker must be replaced |
Fault codes and symptom→remedy steps extracted from this unit’s service/owner documentation; verify against the official manual before servicing.