HomeLight TowersAthlon AG164T16

Athlon AG164T16 Light Tower

The Athlon AG164T16 is a light tower.

0
Parts

Troubleshooting

16

Symptoms & remedies

SymptomCauseRemedy
Unit is shortedFlash rotor Faulty windings Pinched leads Faulty capacitor Faulty diodesCheck windings for broken/burned wires; check resistance Examine and correct Replace capacitor Replace diodes
Generator excitation failure (does not maintain voltage)Faulty surge suppressorReplace surge suppressor
Loose or broken lead wiresCheck leads for broken wires or loose connections; check wiring diagram
Full voltage at no load, voltage drops at full loadRotor opened or shortedMeasure resistance between leads
Fast engine speedAdjust engine speed
High No-Load VoltageHigh capacity capacitorReplace capacitor
Loss of residual magnetismFlash rotor
Low engine speedAdjust engine speed
Low Voltage under loadFaulty diodeReplace diode
High voltage under loaded conditionsIncorrect engine adjustmentCheck engine speed & operation
No voltageFaulty suppressorDisconnect suppressor. If voltage rises, replace suppressor and reconnect.
Incorrect voltage adjustment and/or operationCheck engine speed and fuel system
Loose connectionInspect connections
Faulty ground connectionInspect connections
Unstable voltageLoad inducedFilter load
Noisy alternatorWorn bearingsReplace bearings

Fault codes and symptom→remedy steps extracted from this unit’s service/owner documentation; verify against the official manual before servicing.

About

Athlon AG164T16 — light tower. Specifications and parts compiled from manufacturer documents.

Find parts

Service & wear parts for the Athlon AG164T16.

Browse parts catalog