HomeCompressorsIngersoll Rand 1720B

Ingersoll Rand 1720B Air Compressor

The Ingersoll Rand 1720B is a air compressor.

0
Parts

Troubleshooting

4

Symptoms & remedies

SymptomCauseRemedy
Low powerDirty Air Screen and/or Exhaust SilencerRemove the Air Strainer Screen and/or Exhaust Silencer and clean using a suitable cleaning solution.
Motor will not runIncorrect assembly of the motorDisassemble the motor and replace worn or broken parts; reassemble as instructed.
Insufficient lubricant in impact mechanismRemove the Hammer Case Assembly and lubricate the impact mechanism.
Tool will not impactBroken or worn impact mechanism partsRemove the Hammer Case Assembly and examine impact mechanism parts. Replace any worn or broken parts.

Fault codes and symptom→remedy steps extracted from this unit’s service/owner documentation; verify against the official manual before servicing.