Troubleshooting
6Fault codes
| Code | Meaning | Cause | Remedy |
|---|---|---|---|
| F1 | Fuse F1 protects the blower motor from overload — If F1 opens, the blower stops | Circuit breaker or fuse opens, usually indicating a more serious problem exists | Check fuse, and replace if needed; Open fuse holder block to access fuse F1; Close fuse holder; Reinstall top cover; Contact a Factory Authorized Service Agent. |
Symptoms & remedies
| Symptom | Remedy |
|---|---|
| Motor/blower will not start or continue running | Check input power connection; Check fuse F1, and replace if open (see Section 7-4); Check motor brushes (see Section 7-3); Have Factory Authorized Service Agent check unit. |
| Air flow cannot be adjusted | Tighten Air Flow Control knob mounting screw. |
| Decreased air flow | Reconnect collection hose to connection port; Inspect collection hose and replace if damaged; Remove obstruction from inside of collection hose; Clean or replace filter (see Section 7-2); Have Factory Authorized Service Agent check unit. |
| Fume extractor discharges fumes or particles | Inspect filter (including gasket) and replace if damaged or dirty. Be sure filter is installed properly. (See Section 7-2); Check seal between upper and lower units; Tighten filter mounting screws; Have Factory Authorized Service Agent check unit. |
| Filter Monitoring light stays On | Clean or replace filter (see Section 7-2); Check for obstruction in grommet and fitting (static pressure sensing passage) in filter case section (see Section 7-2). |
Fault codes and symptom→remedy steps extracted from this unit’s service/owner documentation; verify against the official manual before servicing.